UNI-T UT593 Multifunction Loop and RCD Tester

UNI-T UT593 Multifunction Loop and RCD Tester

Regular price Rs 246,500.00 LKR
Regular price Sale price Rs 246,500.00 LKR
Sale Sold out
Tax included. Shipping calculated at checkout.
Get a Quote via WhatsApp

HOT LINE 077-8620567 NANO ZONE TRADING

UNI-T UT593 Loop and RCD Tester in Sri Lanka

Multifunction Tester for RCD, Earth Loop Impedance, Insulation and Continuity

The UNI-T UT593 Multifunction Loop and RCD Tester combines RCD testing with earth loop impedance, line impedance, continuity, insulation resistance, voltage, frequency and phase rotation checks in one instrument. It also displays prospective fault current (up to 26 kA) from loop and line measurements, so electricians can inspect and maintain an installation with one tool instead of several meters. Browse our full range of RCD Testers in Sri Lanka.

The Auto RCD test runs the ×½, ×1 and ×5 tests at both 0° and 180° from a single press of the TEST button, then stores the results for recall. The Ramp test finds the trip current, and the tester also offers AC and pulsating DC (half-wave and full-wave) test types. Loop and RCD functions are specified for 220V ±10%, which includes Sri Lanka's 230V supply. It is rated CAT III 300V and is intended for 220V single-phase RCD and loop tests. The UT593 has no ×2 RCD test, which is available on the UNI-T UT595. Every unit ships with the manufacturer's calibration certificate, batteries included and a one-year warranty.

Technical Specifications

RCD Test
Operating voltage: 220V ±10%, 45~65Hz | Test current: 10/30/100/300/500 mA | Tests: ×½, ×1, ×5, Auto and Ramp | Trip time: ×½ up to 2000 ms, ×1 up to 500 ms, ×5 up to 40 ms | Trip time accuracy: ±(5%+5) | Trip current range: ½ to 1.1 × IΔn (7 test points) | Trip current accuracy: ±10%
Loop Impedance (L-E)
220V ±10%, 45~65Hz | 0.05~2000Ω (0.05~1.99Ω, 2.0~19.9Ω, 20~2000Ω) | Test current: 20A for 20 ms | Accuracy: ±(5%+5) | Prospective fault current: 0~26 kA
Line Impedance (L-N)
195~440V, 45~65Hz | 0.05~2000Ω | Test current: 20A for 20 ms | Accuracy: ±(5%+5) | Prospective short-circuit current: 0~26 kA
NO-TRIP Loop Impedance
Measuring scope: 1.00~2000Ω | 20A test current | Switch between L-N and L-PE measurements
Continuity
0.01~200Ω | Test current above 200 mA (0.00~2.00Ω) | Accuracy: ±(2%+5) | Zero function and 20Ω buzzer compare
Insulation Resistance
250V: 0.05~250 MΩ | 500V: 0.05~500 MΩ | 1000V: 0.05~1000 MΩ | Accuracy: ±(5%+5) | Auto discharge | 2 MΩ buzzer compare
Voltage and Frequency
AC: 0~440V (50/60Hz, below 10V for reference only) | DC: 0~±440V | Accuracy: ±(2%+3) | Frequency: 20~100Hz (reference only)
Phase Rotation
Three-phase 100~440V, 45~65Hz | Forward and reversed rotation indication | Open phase detection
Display
LCD, 9999 counts | Auto ranging | Backlight (F1 key) | Over-load indication | Low battery indication
Battery
8 × 1.5V AA alkaline
Safety
CAT III 300V | Pollution degree 2 | IEC 61010 compliant design
Operating | Storage Conditions
0°C~40°C (up to 85%RH) | -20°C~60°C (up to 90%RH)
Size and Weight
210 × 175 × 90 mm | 1 kg including batteries
Calibration and Warranty
Manufacturer's calibration certificate included | 1-year warranty

Key Features

Auto RCD Test
Runs six RCD tests (×½, ×1 and ×5 at 0° and 180°) in sequence, stores the data and lets you review it with the F3 key
Earth Loop and Line Impedance
Measures L-PE and L-N impedance and shows prospective fault and short-circuit current
RCD Trip Current (Ramp) Test
Finds the current at which the RCD trips and shows the trip time
AC and Pulsating DC Test Types
Select AC or DC (full-wave and half-wave) test waveforms, plus a 30-second countdown timer mode
Insulation and Continuity Testing
250V, 500V and 1000V insulation tests, and a 200 mA continuity test with lead zeroing
Voltage, Frequency and Phase Rotation
Automatic AC/DC voltage detection, frequency reading and three-phase sequence check
Wiring Warnings
L-PE, L-N and N-PE indicators flash when the supply, earth, neutral or live/neutral connection is wrong
Test Lock Function
Locks the continuity and insulation tests for long measurements

Applications

  • Electrical installation inspection and maintenance
  • RCD trip time and trip current testing
  • Earth fault loop impedance and prospective fault current checks
  • Insulation resistance and continuity testing of wiring and equipment
  • Three-phase sequence checks before connecting motors

Which Tester Should You Choose?

The UT593 is a good fit when you need loop, insulation and RCD tests in one tool. If you test RCDs more than anything else, the UNI-T UT582+ single phase RCD tester is a simpler and more compact choice. Do not test live circuits in continuity or insulation modes. The RCD and loop tests operate on a live 220V supply, so follow the safety instructions in the manual. The listed ratings are CAT III 300V.

Package Includes

  • 1 x UNI-T UT593 Multifunction Tester
  • 8 x 1.5V AA batteries
  • 1 x Test lead set
  • 1 x Carrying bag
  • 1 x Manufacturer's calibration certificate
  • 1 x User manual